Search

Refine Results
International Classification for Standards (ICS) code
Source
Standards Development Organization (SDO) code
Language
Status
National Standards of Canada (NSC) code
Period range

From

To

Displaying 501 - 510 of 1099
Systems and software engineering - Systems and software Quality Requirements and Evaluation (SQuaRE)...
ISO/IEC 25000:2014 provides guidance for the use of the new series of International Standards named Systems and software Quality Requirements and Evaluation (SQuaRE). The purpose of ISO/IEC 25000:2014 is to provide a general overview of SQuaRE contents, common reference models and definitions, as well as the relationship among the documents, allowing users of the Guide a good understanding of…
Publisher :
IEC
Status :
Published
Published Date :
2014-03-13
ICS Code(s) :
35.080
Systems and software engineering — Systems and software Quality Requirements and Evaluation (SQuaRE)...
ISO/IEC 25000:2014 provides guidance for the use of the new series of International Standards named Systems and software Quality Requirements and Evaluation (SQuaRE). The purpose of ISO/IEC 25000:2014 is to provide a general overview of SQuaRE contents, common reference models and definitions, as well as the relationship among the documents, allowing users of the Guide a good understanding of…
Publisher :
ISO
Status :
Published
Published Date :
2014-03-13
ICS Code(s) :
35.080
Medical electrical equipment - Part 1: General requirements for basic safety and essential performan...
Scope, object and related standards 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that…
Publisher :
CSA
Status :
Standard
Published Date :
2014-02-28
ICS Code(s) :
11.040
Medical electrical equipment — Part 2-47: Particular requirements for the basic safety and essential...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. 201.1 Scope, object and related standards Clause 1 of the general standard1 applies, except as follows: 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of AMBULATORY…
Publisher :
CSA
Status :
Standard
Published Date :
2014-02-28
ICS Code(s) :
11.040.55
Medical electrical equipment — Part 2-6: Particular requirements for the basic safety and essential ...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. 201.1 Scope, object and related standards Clause 1 of the general standard1 applies, except as follows: 201.1.1 * Scope Replacement: This International Standard specifies requirements for the safety of MICROWAVE THERAPY EQUIPMENT used in…
Publisher :
CSA
Status :
Standard
Published Date :
2014-02-28
ICS Code(s) :
11.040.60
Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. 1 Scope 201.1 Scope, object and related standards IEC 60601-1:2005, Clause 1 applies, except as follows: 201.1.1 * Scope Replacement: This International Standard specifies particular requirements for the BASIC SAFETY and ESSENTIAL PERFORMANCE…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2014-02-28
ICS Code(s) :
11.040.10
Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential per...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. Subclause 1.1 of The general standard is replaced by: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETER EQUIPMENT intended for use on humans, hereafter referred to as ME EQUIPMENT. This includes any part…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2014-02-28
ICS Code(s) :
11.040.10
Medical electrical equipment — Part 2-16: Particular requirements for the basic safety and essential...
This Standard covers ME EQUIPMENT that is intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I. This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HAEMODIALYSIS, HAEMODIAFILTRATION and HAEMOFILTRATION EQUIPMENT, hereafter referred to as HAEMODIALYSIS EQUIPMENT. This International Standard does not take into…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2014-02-28
ICS Code(s) :
11.040.20; 11.040.25
Medical electrical equipment - Part 2-3: Particular requirements for the basic safety and essential ...
This is the second edition of CAN/CSA-C22.2 No. 60601-2-3, Medical electrical equipment - Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-3 (third edition, 2012-04). It supersedes the previous…
Publisher :
CSA
Status :
Standard
Published Date :
2014-02-28
ICS Code(s) :
11.040.60; 13.110
Liquid petroleum products — Determination of hydrocarbon types and oxygenates in automotive-motor ga...
ISO 22854:2014 specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline and automotive ethanol fuel (E85). Additionally, the benzene content, oxygenate compounds and the total oxygen content can be determined. This International Standard defines two procedures, A and B. Procedure A is applicable to automotive…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2014-02-20
ICS Code(s) :
75.080