Medical electrical equipment — Part 2-28: Particular requirements forthe basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-RAY
TUBE ASSEMBLIES and to components thereof:
– hereafter referred to as ME EQUIPMENT;
– intended for medical diagnosis and imaging.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will…
Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 32:2012 International Standard applies to multimedia equipment (MME) having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. Equipment within the scope of CISPR 13 or CISPR 22 is within the scope of this publication. MME intended primarily for professional use is within the scope of this publication. The radiated emission requirements in this standard are not intended to be…
Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essentialperf...
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL
THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This standard specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This standard applies to all electrical CLINICAL THERMOMETERS that are used for…
Medical electrical equipment — Part 2-35: Particular requirements for the basic safety and essential...
201.1.1 * Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as
ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this
International Standard.
If a clause or subclause is specifically intended to be applicable to ME…
Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<i&g...
IEC 62067:2011 is available as IEC 62067:2011 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62067:2011 specifies test methods and requirements for power cable systems, cables with extruded insulation and their accessories for fixed installations, for rated voltages above 150 kV (Um = 170…
Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<i>...
IEC 60840:2011 is available as IEC 60840:2011 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60840:2011 specifies test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 30 kV (Um = 36 kV) up to and…
Medical Electrical Equipment - Part 2-45: Particular Requirements for the Safety of Mammographic X-R...
201.1.1 Scope
Replacement:
This international standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MAMMOGRAPHIC X-RAY EQUIPMENT and MAMMOGRAPHIC STEREOTACTIC DEVICES, hereafter also
referred to as ME EQUIPMENT.
NOTE 1 This includes MAMMOGRAPHIC X-RAY EQUIPMENT using integrated digital X-RAY IMAGE RECEPTORS or integrated storage phosphor subsystems.
Excluded from the…
Medical electrical equipment — Part 2-43: Particular requirements forthe basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-RAY
EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED
INTERVENTIONAL PROCEDURES, hereafter referred to as INTERVENTIONAL X-RAY EQUIPMENT. Its
scope excludes, in particular:
– equipment for RADIOTHERAPY;
– equipment for COMPUTED TOMOGRAPHY;
– ACCESSORIES intended to be…
Iron ores — Determination of the moisture content of a lot
This International Standard specifies a method for the determination of the moisture content of a lot of iron ore.
This method is applicable to all iron ores, whether natural or processed.
Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential...
IEC 60601-2-31:2008+A1:2011 consists of the second edition (2008) and its amendment 1 (2011). The technical content is therefore identical to the base edition and its amendment and has been prepared for user convenience. IEC 60601-2-31:2008 applies to the basic safety and essential performance of external pacemakers powered by an internal electrical power source. The minimum safety requirements…