Search

Refine Results
International Classification for Standards (ICS) code
Source
Standards Development Organization (SDO) code
Language
Status
National Standards of Canada (NSC) code
Period range

From

To

Displaying 41 - 50 of 174
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills,...
IEC 60335-2-9:2019 deals with the safety of electric portable appliances for household and similar purposes that have a cooking function such as baking, roasting and grilling, their rated voltage being not more than 250 V. Examples of appliances that are within the scope of this standard are: – barbecues for indoor use; – breadmakers; – candy floss appliances; – contact grills (griddles…
Publisher :
IEC
Status :
Published
Published Date :
2019-05-16
ICS Code(s) :
13.120; 97.040.50
General-use snap switches
1 Scope 1.1 The requirements of this Standard apply to manually operated, general-use snap switches for connection to copper (Cu) or copper-clad conductors used in accordance with the National Electrical Code(NEC), ANSI/NFPA 70, or the Canadian Electrical Code (CE Code), Part I, and and intended to be permanently connected in accordance with the NEC and the CE Code, Part I. In Canada,…
Publisher :
CSA
Status :
Standard
Published Date :
2018-07-19
ICS Code(s) :
29.120.40
Wire connectors
1 Scope 1.1 This Standard applies to single-polarity connectors for use with all alloys of copper or aluminum, or copper-clad aluminum conductors, or all three, for providing contacts between current-carrying parts, in accordance with the Canadian Electrical Code, Part I, C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical…
Publisher :
CSA
Status :
Standard
Published Date :
2018-03-31
ICS Code(s) :
29.120.20
Flatiron and appliance plugs
cooking or heating appliances rated up to 20 A, 250 Volts or less, intended for use in ordinary non-hazardous locations – all intended for connection to a branch circuit for use in accordance with the National Electrical Code, NFPA 70 and the Canadian Electrical Code, Part I, CSA C22.1-15. 1.2 This Standard does not directly apply to the following devices, but may be used to supplement the…
Publisher :
CSA
Status :
Standard
Published Date :
2017-03-31
ICS Code(s) :
29.120.30
Plugs, receptacles, and cable connectors of the pin and sleeve type
1.1 This standard applies to pin and sleeve type plugs, receptacles, power inlets, and connectors, rated up to 800 amperes and up to 600 volts ac or dc, and which may include up to eight pilot contacts. These devices are intended to provide power from branch circuits, or are for direct connection to the branch circuit in accordance with the Canadian Electrical Code Part I, the National…
Publisher :
CSA
Status :
Standard
Published Date :
2017-01-31
ICS Code(s) :
29.120.30
Vented gas-fired space heating appliances
1.1 This Standard applies to newly produced vented gas-fired space heating appliances (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W). These appliances are for use with: a) natural gas; b) manufactured gas; c) mixed gas; d) propane gas […
Publisher :
CSA
Status :
Standard
Published Date :
2016-12-31
ICS Code(s) :
97.100.20
Low-voltage switchgear and controlgear — Part 7-1: Ancillary equipment — Terminal blocks for copper ...
This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to connect round copper conductors, with or without special preparation, having a cross-…
Publisher :
CSA
Status :
Standard
Published Date :
2016-12-31
ICS Code(s) :
29.130.20
Low-voltage switchgear and controlgear — Part 7-2: Ancillary equipment — Protective conductor termin...
This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function up to 120 mm2 (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and above 10 mm2 (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial applications. NOTE: AWG is the abbreviation of “American Wire Gage” [Gage (US) = Gauge (…
Publisher :
CSA
Status :
Standard
Published Date :
2016-12-31
ICS Code(s) :
29.120.99; 29.120.20
Low-voltage switchgear and controlgear — Part 7-3: Ancillary equipment — Safety requirements for fus...
1.1 Scope This part of IEC 60947 applies to fuse terminal blocks with screw-type or screwless-type clamping units for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not exceeding 1 000 V a.c., up to 1 000 Hz or 1 500 V d.c., and having a…
Publisher :
CSA
Status :
Standard
Published Date :
2016-12-31
ICS Code(s) :
29.120.99; 29.130.20
Self-ballasted lamps and lamp adapters
1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code Part I, CSA C22.1, in non-hazardous…
Publisher :
CSA
Status :
Standard
Published Date :
2016-12-31
ICS Code(s) :
29.140; 29.140