Protective clothing for use in welding and allied processes
ISO 11611:2015 specifies minimum basic safety requirements and test methods for protective clothing including hoods, aprons, sleeves, and gaiters that are designed to protect the wearer's body including head (hoods) and feet (gaiters) and that are to be worn during welding and allied processes with comparable risks. For the protection of the wearer's head and feet, this International…
Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test
IEC 60068-2-60:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60068-2-60:2015 determines the corrosive influence of operating and storage indoor environments on…
Live working-Electrical insulating sleeves
Travaux sous tension-Protège-bras isolants électriques
1 Scope
This International Standard is applicable to electrical insulating sleeves for the protection of
workers from accidental contact with live electrical conductors, apparatus or circuits.
The products designed and manufactured according to this standard contribute to the safety
of the users provided they are used by skilled persons, in accordance with safe methods of
work and the…
Ophthalmic optics — Contact lens care products — Method for evaluating Acanthamoeba encystment by co...
ISO 19045:2015 specifies a method for evaluating the potential of products for contact lens disinfection to induce encystment of Acanthamoeba species. This method excludes the evaluation of oxidative systems that require a special lens case for use. This International Standard does not address the evaluation of disinfection efficacy of contact lens disinfecting products.
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar ap...
CISPR 14-2:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
CISPR 14-2:2015 deals with the electromagnetic immunity of appliances and similar apparatus for household and similar…
Identification cards — Recording technique — Part 7: Magnetic stripe — High coercivity, high density
ISO/IEC 7811-7:2014 is one of a series of International Standards describing the characteristics for identification cards as defined in the definitions clause and the use of such cards for international interchange.
It specifies requirements for a high coercivity magnetic stripe (including any protective overlay) on an identification card and encoding technique. It takes into consideration both…
Identification cards - Recording technique - Part 7: Magnetic stripe - High coercivity, high density
ISO/IEC 7811-7:2014 is one of a series of International Standards describing the characteristics for identification cards as defined in the definitions clause and the use of such cards for international interchange.
It specifies requirements for a high coercivity magnetic stripe (including any protective overlay) on an identification card and encoding technique. It takes into consideration both…
Protective clothing for protection against chemicals — Classification,labelling and performance requ...
This National Standard of Canada is based on International Standard ISO 16602:2007+A1:2012, MOD.
This International Standard establishes minimum performance classification and labelling requirements for
protective clothing designed to provide protection against chemicals. Protective clothing items covered by this
International Standard include, but may not be limited to, totally…
Low-voltage switchgear and controlgear — Part 5-1:Control circuit devices and switching elements — E...
This part of IEC 60947 applies to CONTROL CIRCUIT DEVICES and SWITCHING ELEMENTS intended for controlling,
signalling, interlocking, etc., of switchgear and controlgear.
It applies to CONTROL CIRCUIT DEVICES having a rated voltage not exceeding 1 000 V a.c. (at a frequency not
exceeding 1 000 Hz) or 600 V d.c.
However, for operational voltages below 100 V a.c. or d.c., see note 2 of 4.3.1.1…
Anaesthetic and respiratory equipment — Compatibility with oxygen
1* Scope
This International Standard specifies requirements for the oxygen compatibility of materials, components and
devices for anaesthetic and respiratory applications, which can come into contact with oxygen in normal
condition or in single fault condition at gas pressures greater than 50 kPa.
Additionally, this International Standard gives general guidelines for the selection of materials…