Medical electrical equipment - Part 2-29: Particular requirements for the safety of radiotherapy sim...
This National Standard of Canada is equivalent to International Standard CEI/IEC 60601-2-29:1999 (second edition, 1999-01).
1 Scope and object
1.1 Scope
Addition:
This Particular Standard applies to RADIOTHERAPY SIMULATORS:
- that use diagnostic X-RAY EQUIPMENT to simulate physically a RADIOTHERAPY RADIATION BEAM, so that the TREATMENT VOLUME to be subjected to IRRADIATION during…
Medical electrical equipment - Part 2-39: Particular requirements for the safety of peritoneal dialy...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-39:1999 (first edition, 1999-06).
1 Scope and object
This clause of the General Standard applies except as follows:
1.1 Scope
Addition:
This Particular Standard specifies the minimum safety requirements for PERITONEAL DIALYSIS EQUIPMENT as defined in 2.1.102, hereinafter referred to as EQUIPMENT. It applies…
Medical electrical equipment - Part 2-41: Particular requirements for the safety of surgical luminai...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-41:2000 (first edition, 2000-02).
1 Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope
Addition:
This Particular Standard details the requirements to be applied to SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS as defined in 2.101 to 2.105, hereinafter referred to as…
Medical electrical equipment - Part 2-13: Particular requirements for the safety of anaesthetic work...
This National Standard of Canada is based on International Standard IEC 60601-2-13:1998 (second edition, 1998-05).
1 Scope and object
This clause of the General Standard applies, except as follows:
Addition
1.2 This Particular Standard presents particular requirements for ANAESTHETIC WORKSTATIONS for inhalational anaesthesia intended for human use supplied complete, as well as particular…
Standard For Smoke Detectors For Fire Alarm Systems
1. Scope
1.1
This standard sets forth requirements for ionization-type and photoelectric-type detectors, rated at 300 V or less, to be employed in ordinary indoor locations in accordance with the following:
A Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524;
B National Building Code of Canada;
C National Fire Code of Canada.
1.2
A smoke detector (e.g.…
Fire hazard testing - Part 5-2: Corrosion damage effects of fire effluent - Summary and relevance of...
IEC TS 60695-5-2:2002 Gives a summary of the test methods that are used in the assessment of the corrosivity of fire effluent. It presents a brief summary of test methods in common use, either as international standards or national or industry standards. It includes special observations on their relevance, for electrotechnical products and their materials, to real fire scenarios and gives…
1 Scope
"This is the common UL and ULC Standard for Dry Chemical Fire Extinguishers. It is the second edition of CAN/ULC-S504, and the tenth edition of UL 299.
These requirements cover the construction and performance, exclusive of performance during fire tests, of portable dry chemical and dry powder (Class D) fire extinguishers. Dry chemical and dry powder fire extinguishers are intended…
Standard for the Rating and Testing of Fire Extinguishers
1 Scope
"These requirements cover rating, and performance during fire tests, of fire extinguishers intended
for use in attacking Class A, B, C, D, and K fires as defined herein. These requirements also
cover performance during fire tests of fire extinguishing agents for application on Class D fires.
The ultimate rating of an extinguisher or the prescribed use of an extinguisher or fire…
1 Domaine d?application
"Ce document constitue la norme harmonisée UL et ULC, Extincteurs à poudres chimiques. Il s’agit de la deuxième édition de la norme CAN/ULC-S504, et de la dixième édition de la norme ANSI/UL 299.
Ces exigences visent la construction et le fonctionnement des extincteurs portatifs à poudre chimique de classe D. Elles ne visent toutefois pas le fonctionnement au…
Standard for Alarm Initiating and Supervisory Devices for Water Type Extinguishing Systems
1. Scope
1.1 This Standard contains requirements for alarm Initiating and Supervisory Detection Devices for attachment to water type extinguishing systems (such as wet, dry and deluge type sprinklers, residential sprinklers, water mist suppression systems, and standpipe systems), as follows:
A Alarm Initiating Devices, including but not limited to:
(i) Vane and paddle type…