Evaluation of human exposure to electromagnetic fields from a stand-alone broadcast transmitter (30 ...
IEC 62577:2009 applies to a single stand-alone broadcast transmitter operating in the frequency range 30 MHz to 40 GHz when put on the market. The objective of the standard is to specify, for such equipment operating in typical conditions, the method for assessment of compliance distances according to the basic restrictions (directly or indirectly via compliance with reference levels) related to…
Publisher :
IEC
Status :
Published
Published Date :
2009-08-27
ICS Code(s) :
13.280; 13.280
Smoke Detectors for Fire Alarm Systems
1.1 This Standard sets forth requirements for smoke detectors and mechanical guards to be employed in ordinary indoor locations in accordance with the following: In the United States: a) National Fire Alarm Code, NFPA 72. In Canada: b) Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524; c) National Building Code of Canada; and d) National Fire Code of Canada. 1.2 A smoke detector (…
Publisher :
ULC
Status :
Withdrawn
Published Date :
2009-08-13
ICS Code(s) :
13.220.20; 13.320
Air-, cable-, and frame-supported membrane structures
1 Scope 1.1 This Standard provides requirements for the design, fabrication, installation, and maintenance of single-membrane structures that are either reinforced or unreinforced and that are air-supported, frame-supported, or cable-supported. 1.2 The general requirements, structural design methods, loadings, and limit states specified in this Standard are intended to be consistent with the…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2009-07-31
ICS Code(s) :
91.080.99
STANDARD FOR FACTORY-BUILT GREASE DUCTS
This Standard covers factory-built grease ducts and grease duct assemblies that are intended to be installed as alternatives to the grease ducts constructed of all welded 1.37 mm carbon steel or 1.09 mm stainless steel required by ULC-S650, Standard for the Installation and Performance of Ventilation and Fire Suppression Systems for Commercial and Institutional Cooking Equipment. Grease…
Publisher :
ULC
Status :
Standard
Published Date :
2009-07-31
ICS Code(s) :
97.040.20; 91.140.30
NORME SUR LES CONDUITS DE GRAISSE PRÉFABRIQUÉS
Les présentes exigences portent sur les conduits de graisse et les ensembles conduit de graisse préfabriqués pouvant être installés à la place des conduits de graisse en acier au carbone de 1,37 mm entièrement soudé ou en acier inoxydable de 1,09 mm, requis en vertu de la norme ULC-S650, Standard for the Installation and Performance of Ventilation and Fire Suppression Systems for Commercial…
Publisher :
ULC
Status :
Standard
Published Date :
2009-07-31
ICS Code(s) :
97.040.20; 91.140.30
Installation code for oil-burning equipment
Scope 1.1 This Code applies to the installation of appliances, equipment, components, and accessories where oil is used for fuel purposes in applications that include (a) space heating; (b) service water heating; (c) power generation; and (d) process application. 1.2 This Code provides minimum requirements for installing or altering all stationary and portable oil-burning equipment, including (…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2009-07-31
ICS Code(s) :
91.140.10; 27.060.10
Self-Ballasted Lamps and Lamp Adapters
1 Scope 1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-, pin-base, and recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, in non-hazardous locations…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2009-07-31
ICS Code(s) :
29.140; 29.140
Cereals — Determination of bulk density, called mass per hectolitre — Part 2: Method of traceability...
ISO 7971-2:2009 specifies a test method for ensuring the traceability of mass per hectolitre measuring instruments through reference to standard measurement instruments. The mass per hectolitre or bulk density is of commercial importance for grain cereals. Several types of instruments with varying performances exist for measuring it. ISO 7971-2:2009 also specifies the performances required of…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2009-07-30
ICS Code(s) :
67.060
Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
IEC 60800:2009 is applicable to, and specifies requirements for, resistive heating cables for low temperature applications such as comfort heating and the prevention of ice formation. These cables and cable sets may comprise either factory fabricated or field (work-site) assembled units, and which are heating cables assembled in accordance with manufacturer's instructions. Bare conductors…
Publisher :
IEC
Status :
Revised
Published Date :
2009-07-22
ICS Code(s) :
29.060.20
LIVE WORKING – CONDUCTIVE CLOTHING FOR USE AT NOMINAL VOLTAGE UP TO 800 kV A.C. AND ± 600 kV D.C.
This National Standard of Canada is based on International Standard CEI/IEC 60895:2002. This National Standard of Canada is applicable to conductive clothing, either assembled from component parts or forming a single complete clothing, worn by (electrically) skilled persons during live working (especially bare-hand working) at a nominal power system voltage up to 800 kV a.c. and ± 600 kV d.c…
Publisher :
ULC
Status :
Withdrawn
Published Date :
2009-06-30
ICS Code(s) :
13.260; 13.260