Wire connectors (Tri-national standard, with UL 486A-486B and NMX-J-543-ANCE)
Scope 1.1 This Standard applies to single-polarity connectors for use with all alloys of copper or aluminum, or copper-clad aluminum conductors, or all three, for providing contacts between current-carrying parts, in accordance with the Canadian Electrical Code, Part I, C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-12-31
ICS Code(s) :
29.120.20
Splicing wire connectors (Tri-national standard, with UL 486C and NXM-J- 548-ANCE)
Scope 1.1 This Standard applies to single-polarity, hand- or tool-applied splicing wire and cable connectors intended for use with all alloys of copper, aluminum conductors, or copper-clad aluminum conductors, or all three, in accordance with the Canadian Electrical Code Part I, C22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-12-31
ICS Code(s) :
29.060; 29.120.20
Positioning devices (Bi-national standard, with UL 1565)
Scope 1.1 This standard applies to those metallic and nonmetallic devices used for positioning - which may include bundling and securing - or to a limited extent supporting cable, wire, conduit, or tubing of a wiring system in electrical installations, to reduce the risk of fire, electric shock, or injury to persons. This standard applies to, but is not limited to, cable clamps, cable and…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-12-31
ICS Code(s) :
29.100.01
Molded-case circuit breakers, molded-case switches and circuit-breaker enclosures (Tri-national sta...
Scope 1.1 The requirements of this standard cover molded-case circuit breakers, circuit breaker and ground-fault circuit-interrupters, fused circuit breakers, high-fault protectors, and high-fault modules. These circuit breakers are specifically intended to provide service entrance, feeder, and branch circuit protection in accordance with the National Installation Codes in Annex B, Ref. No.1.…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-12-31
ICS Code(s) :
29.120.40; 29.120.50
Information technology — Security techniques — Information security management for inter-sector and ...
1 Scope This International Standard provides guidelines in addition to guidance given in the ISO/IEC 27000 family of standards for implementing information security management within information sharing communities. This International Standard provides controls and guidance specifically relating to initiating, implementing, maintaining, and improving information security in inter-organizational…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-12-31
ICS Code(s) :
35.040
Household and similar electrical appliances - Safety - Part 2-75: Particular requirements for commer...
IEC 60335-2-75:2012 deals with the safety of electric commercial dispensing appliances and vending machines for preparation or delivery of food, drinks and consumer products, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are within the scope of this standard are bulk tea or coffee brewing machines, cigarette…
Publisher :
IEC
Status :
Published
Published Date :
2012-12-13
ICS Code(s) :
55.230
Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers...
IEC 60335-2-8:2012 deals with the safety of electric shavers, hair clippers and similar appliances intended for household and similar purposes, their rated voltage being not more than 250 V. Examples of similar appliances are those used for manicure and pedicure. Appliances not intended for normal household use, but which nevertheless may be a source of danger to the public, such as appliances…
Publisher :
IEC
Status :
Revised
Published Date :
2012-12-12
ICS Code(s) :
13.120; 97.170
Household and similar electrical appliances - Safety - Part 2-41: Particular requirements for pumps
IEC 60335-2-41:2012 deals with the safety of electric pumps for liquids having a temperature not exceeding 90 °C, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances within the scope of this standard are aquarium pumps, pumps for garden ponds, shower-boost pumps, sludge pumps…
Publisher :
IEC
Status :
Revised
Published Date :
2012-12-10
ICS Code(s) :
13.120; 13.120
Household and similar electrical appliances — Safety — Part 2-31:Particular requirements for range h...
1 Scope This clause of Part 1 is replaced by the following. This International Standard deals with the safety of electric range hoods and other cooking fume extractors intended for installing above, beside, behind or under household cooking ranges, hobs and similar cooking appliances, their rated voltage being not more than 250 V. NOTE 101 The cooking appliance may be supplied by electricity…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-11-30
ICS Code(s) :
13.120; 97.040.20
The ISO 50001 Essentials - Energy Management Systems Implementation Guideline
Detailed Information Objective of this handbook This is the first edition of the ISO 50001 essentials handbook. The objective of this handbook is to provide user-friendly guidance to enterprises who wish to implement an ISO 50001-conformant Energy Management System (EnMS), and in the longer term to accomplish continual improvement in energy performance through effective operation and maintenance…
Publisher :
CSA
Status :
Standard
Published Date :
2012-11-30
ICS Code(s) :
27.010