Concrete materials and methods of concrete construction/Test methods and standard practices for conc...
1.1 General This Standard provides the requirements for materials and methods of construction for (a) cast-in-place concrete and concrete precast in the field; and (b) residential concrete used in the construction of buildings conforming to Part 9 of the National Building Code of Canada (NBCC). 1.2 This Standard does not specify the following: (a) requirements for the design of concrete…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2015-08-31
ICS Code(s) :
91.080.40; 91.100.30
Fume hoods and associated exhaust systems
1.1 This Standard applies to all types of laboratory fume hoods, except for ductless fume hoods. Note: Ductless fume hoods should not be considered acceptable substitutes for ducted fume hoods. Some jurisdictions prohibit use of ductless fume hoods with certain chemicals. For these reasons, ductless fume hoods have not been included in this Standard. 1.2 This Standard specifies a) safety…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2015-08-31
ICS Code(s) :
91.140.30
Automatic electrical controls for household and similar use — Part 2-9: Particular requirements for ...
1.1 [Add the following paragraph] This Standard applies to the safety of such equipment designed and constructed for installation and use in accordance with CSA C22.1, Canadian Electrical Code (CE Code), Part I. 1.5 Normative references [Add the following] Any reference to International Standards that are adopted as National Standards of Canada subsequent to the publication of CAN/CSA-E60730-2-9…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2015-08-31
ICS Code(s) :
97.120
Gas convenience outlets and optional enclosures
1.1 This Standard applies to gas convenience outlets (see Clause 3, Definitions), hereinafter referred to as gas outlets and optional enclosures, not to exceed 1-1/2 in (38.1 mm) and pressures not to exceed 5 psi (34.5 kPa), capable of operation at temperatures between 32°F and 200°F (0°C and 93.3°C) if intended for indoor use only, or between -20°F and 200°F (-28.8°C and 93.3°C) if intended…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2015-08-31
ICS Code(s) :
75.200
Petroleum and natural gas industries — Specific requirements for offshore structures — Part 3: Topsi...
This part of ISO 19901 gives requirements for the design, fabrication, installation, modification and structural integrity management for the topsides structure for an oil and gas platform. It complements ISO 19902, ISO 19903, ISO 19904-1, ISO 19905-1 and ISO 19906, which give requirements for various forms of support structure. Requirements in this part of ISO 19901 concerning modifications and…
Publisher :
CSA
Status :
Standard
Published Date :
2015-08-31
ICS Code(s) :
75.180.10
Electromagnetic compatibility (EMC) — Part 3-14: Assessment of emission limits for harmonics, interh...
This part of IEC 61000, which is informative in its nature, provides guidance on principles that can be used as the basis for determining the requirements for the connection of disturbing installations to low voltage (LV) public power systems. For the purposes of this part of IEC 61000, a disturbing installation means an installation (which may be a load or a generator) that produces disturbances…
Publisher :
CSA
Status :
Standard
Published Date :
2015-08-31
ICS Code(s) :
33.100.10
STANDARD FOR EGRESS DOOR SECURING AND RELEASING DEVICES
1.1 This Standard shall apply to egress door securing and releasing devices to perform the function of holding a door in the closed position and releasing the door to permit free egress when operated. Egress door securing and releasing devices are considered ancillary devices and are not an integral part of the fire alarm system. 1.2 This Standard covers physical and performance requirements…
Publisher :
ULC
Status :
Standard
Published Date :
2015-08-31
ICS Code(s) :
91.190; 13.220.20
STANDARD FOR ABOVEGROUND PROTECTED TANK ASSEMBLIES FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS
1.1 This Standard covers minimum requirements for shop fabricated aboveground protected tank assemblies that are used for the storage of flammable and combustible liquids with a specific gravity not greater than 1.0, that are compatible with the material of construction. 1.2 These protected tank assemblies consist of primary tanks provided with secondary containment and protective encasement…
Publisher :
ULC
Status :
Standard
Published Date :
2015-08-31
ICS Code(s) :
23.020.10
Household and similar electrical appliances - Safety - Part 2-90: Particular requirements for commer...
IEC 60335-2-90:2015 deals with<br /> - the safety of microwave ovens with a cavity door intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances;<br /> - the safety of combination microwave ovens with a cavity door, the requirements for which are contained in Annex AA;…
Publisher :
IEC
Status :
Published
Published Date :
2015-08-27
ICS Code(s) :
97.040.20
Household and similar electrical appliances - Safety - Part 2-90: Particular requirements for commer...
IEC 60335-2-90:2015 deals with - the safety of microwave ovens with a cavity door intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances; - the safety of combination microwave ovens with a cavity door, the requirements for which are contained in Annex AA; - the safety of…
Publisher :
IEC
Status :
Revised
Published Date :
2015-08-27
ICS Code(s) :
97.040.20