Notice of Intent

Standard for Residential Fire Warning Systems...

CAN/ULC-S540 provides the minimum requirements for the design, installation, inspection, testing and maintenance of residential fire warning systems for use within dwelling units and care occupancies not requiring fire alarm...
Notice of Intent

Standard for Fire Hydrants

This Standard covers dry barrel type hydrants intended for use in piping systems supplying water for fire protection service. Hydrants shall be designed for a minimum working pressure of 1000 kPa. Hydrants of special design...
Notice of Intent

Standard for Smoke Alarms

1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations, in accordance: a) Installation of Smoke Alarms, CAN/ULC-S553; b) National...
Notice of Intent

Standard for Gas Vents

These Requirements cover the design and construction of Type B (round or oval) and Type BW Gas Vents. Type B Gas Vents are intended for the venting of flue gases having temperatures not exceeding 245 °C, from gas-fired...
Notice of Intent

Standard for Factory-Built Fireplaces

1.1 Part A of these requirements covers factory-built fireplaces capable of utilizing solid fuels commonly used in fireplaces and intended for provision of supplementary heating in buildings. These fireplaces are only...
Notice of Intent

Special Purpose plastic tanks

1.1 The following requirements provide the minimum criteria for the material properties and performance of nonmetallic containers of the non-pressure type, intended to bulk store and dispense combustible (such as new...
Notice of Intent

Standard for Leak Detection Devices (Volumetric...

1.1 This Standard provides minimum requirements for primary containment leak detection that uses quantitative assessment of physical characteristics to detect leaks in the primary containment. 1.2 These requirements do not...
Notice of Intent

Emergency Valves for Flammable and Combustible...

1.1 This Standard sets forth minimum requirements for emergency valves that are intended to be used for the control of flammable and combustible liquids which are handled at temperatures within the range of -40 °C to +50 °C...
Notice of Intent

Standard Method Of Test For The Evaluation Of...

This test method evaluates the temperature transmission performance of an encapsulation material or assembly of materials installed over a wood substrate when the test specimen is subjected to a standard fire exposure...
Notice of Intent

Standard for Site Quality Assurance Program for...

1.1 This standard outlines requirements for a site quality assurance program (SQAP) for the on-site installation of spray applied polyurethane foam (SPF). As the installation of the material is dependent on the installer, a...
Notice of Intent

Standard for Smoke Alarms

These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations, in accordance: a) Installation of Smoke Alarms, CAN/ULC-S553; b) National Building...
Notice of Intent

Standard for Aboveground Steel Tanks for Fuel...

1.1 This Standard covers the design and construction of aboveground steel non-pressure tanks intended for installation inside or outside buildings and for the storage of: A Combustible liquid intended to be used as heating...