Displaying 1549 - 1560 of 12089
Notice of Intent
Standard for Heat Shields
1.1 These requirements cover the construction and performance of heat shields for vertical installation between heat producing appliances, chimney connectors and combustible construction. 1.2 Heat shields are intended for...
Notice of Intent
Standard for Egress Door Securing and Releasing...
This Standard covers the physical and performance requirements for egress door securing and releasing devices that are intended to hold a door in the closed position and releasing the door to permit free egress when operated...
Notice of Intent
Standard Corner Wall Method Of Test For Flammability...
The proposal is to administratively update the ANSI approval of the Standard and that no technical changes are being proposed, nor have any been made since the date of the last approval
Notice of Intent
Standard for Factory-Built Fireplace Systems
1.1 These requirements cover factory-built fireplace systems capable of utilizing solid fuels, as specified by the manufacturer, and intended for provision of supplementary heating in buildings. These fireplace systems...
Notice of Intent
Standard for Cotton-Synthetic Percolating Forestry...
This Standard applies to woven-jacketed, lined, cotton-synthetic percolating forestry hose which contains non-synthetic fibres of the size commercially known as 38 mm having a minimum service test pressure of 2070 kPa...
Notice of Intent
Standard for Synthetic Percolating Forestry Hose
This Standard applies to 25 and 38 mm synthetic percolating type hoses having a minimum service test pressure of 2070 kPa suitable for use in forest fire suppression. These hoses are classified as follows: Class A: woven...
Notice of Intent
Control units for fire alarm systems
This Standard covers requirements for control units, fire alarm systems and control unit accessories for use in accordance with CAN/ULC‑S524, Standard for the Installation of Fire Alarm Systems, in accordance with Rule 32‑004...
Notice of Intent
Standard for Water Fire Extinguishers
This is the common UL and ULC Standard for Water Fire Extinguishers. These requirements cover the construction and performance, exclusive of performance during fire tests, of water fire extinguishers. Water fire extinguishers...
Notice of Intent
Standard for Carbon-Dioxide Fire Exinguishers
This is the common UL and ULC Standard for Carbon-Dioxide Fire Extinguishers. These requirements cover the construction and performance, exclusive of performance during fire tests, of portable carbon-dioxide fire...
Notice of Intent
Dry Chemical Fire Extinguishers
These requirements cover the construction and performance, exclusive of performance during fire tests, of portable dry chemical and dry powder (Class D) fire extinguishers. Dry chemical and dry powder fire extinguishers are...
Notice of Intent
Standard for Fire and Emergency Service Technical...
These requirements apply to technical rescue rope and water rescue throw rope, and associated equipment used by rescue services. Part A covers the requirements for technical rescue rope used by emergency services for the...
Notice of Intent
Standard for Cotton-Synthetic Percolating Forestry...
This Standard applies to woven-jacketed, lined, cotton-synthetic percolating forestry hose which contain non-synthetic fibres of the size commercially known as 38 mm having a minimum service test pressure of 2070 kPa...