Search

Refine Results
Type
Program
Status
Country
Province
City
Program Specialty Area
Field of Testing
Period range

From

To

Displaying 2953 - 2964 of 3644
Notice of Intent

Meter-mounting devices

This Standard applies to indoor and outdoor meter-mounting devices, either as complete self-contained devices or provided as a part of service equipment, for use in nonhazardous locations, and intended to be employed in...
Notice of Intent

High voltage couplers

1.1 This Standard applies to locking-type, pin and sleeve type plugs, receptacles, power inlets, and connectors and associated integrated accessories (i.e., junction box), rated up to 1,200 amperes (for single-and multi-pole)...
Notice of Intent

Western Red Cedar Shakes and Shingles

1. Scope 1.1 This Standard applies to shakes and shingles manufactured from western red cedar (Thuja plicata Donn ex D. Don) or Alaska (yellow) cedar (Cupressus nootkatensis D. Don). It specifies minimum grading...
Notice of Intent

Spas, hot tubs and associated equipment

1.1 This Standard applies to spas, hot tubs, and associated equipment intended for residential and commercial use indoors or outdoors in nonhazardous locations, installed in accordance with the Rules of the Canadian...
Notice of Intent

Compressed breathing air and systems

1.1 This Standard provides the minimum requirements, unless otherwise specified by the authority having jurisdiction, for the purity of compressed breathing air supplied to the service outlet and for breathing air systems...
Notice of Intent

Control and instrumentation cables

.1 This Standard applies to multiple-conductor control and instrumentation cables (including thermocouple cables and thermocouple extension cables) having a voltage rating not exceeding 1000 V and intended for installation in...
Notice of Intent

Photometric performance of roadway and street...

1.1 This Standard specifies photometric performance requirements for luminaires that are used for roadway and street lighting applications. 1.2 The following light sources are addressed in this Standard: a) clear HPS lamp; b)...
Notice of Intent

Decorative Lighting Products

1.1 This Standard applies to decorative lighting strings, decorative lighting outfits, pre-lit trees, and accessories, intended for seasonal or commercial use connected to circuits of 120 V nominal or less by means of an...
Notice of Intent

Motors and generators

1.1 This Standard applies to electric motors and generators for installation and use, in accordance with the Rules of the Canadian Electrical Code, Part I, in non-hazardous locations. Note: The term "machine" throughout this...
Notice of Intent

Surge protective devices - Type 1 - Permanently...

1.1 This Standard applies to surge protective devices (SPDs) intended for: a) permanently connected applications designed for limiting surge voltages and discharging surge currents; b) use on 50/60 Hz circuits over 42 V and...
Notice of Intent

Surge protective devices - Type 2 - Permanently...

1.1 This Standard applies to surge protective devices (SPDs) intended for a) permanently connected applications designed for limiting surge voltages and discharging surge currents; b) use on 50/60 Hz circuits over 42 V and up...