Notice of Intent
Electric and combustion engine ambulances
Purpose and scope This standard specifies requirements for the design, performance, and safety of equipment in an ambulance (patient compartment) used for the transport and care of patients. The standard also specifies...
Notice of Intent
Standard for Fibre Reinforced Plastic Underground...
1 SCOPE 1.1 This Standard sets forth minimum design and construction requirements for fibre reinforced plastic, non-pressure tanks that are used for the underground storage of flammable and combustible liquids, such as: A...
Notice of Intent
Polyethylene (PE) Pipe for the Transport of Fluids...
PURPOSE This standard specifies the characteristics and test methods relating to solid-wall high-density polyethylene (HDPE) pipe having a hydrostatic design basis greater than or equal to 11 MPa. NOTE — The designer may...
Notice of Intent
Standard for Nonvolumetric Precision Leak Detection...
1.1 This Standard provides minimum requirements for primary containment leak detection that uses qualitative characteristics to detect leaks in the primary containment. NOTE: Depending on the design of the tank system, and...
Notice of Intent
Reaction to fire tests — Room corner test for...
This standard specifies the test method to evaluate the reaction of wall and ceiling products to fire when installed at the surface of a small room and exposed directly to a specified ignition source. The test represents a...
Notice of Intent
Design of concrete structures
1.1 General This Standard specifies requirements, in accordance with the National Building Code of Canada, for the design and strength evaluation of a) structures of reinforced and prestressed concrete; and b) plain concrete...
Publications
Global Perspectives on Standardization: Lessons...
The 17-page report highlights SCC’s two-day strategic exchange held April 14-15, 2014, with its U.S., European and Australian counterparts. Global Perspectives brings together the views of several distinguished leaders of the...
Notice of Intent
Standard for Lining Systems for New Masonry Chimneys
1.1 These requirements cover lining systems for new masonry chimneys . 1.2 Liners are for use with gas, liquid and solid fuel fired residential appliances and building heating equipment, where the flue gas temperatures...
Notice of Intent
Medium-voltage ac contactors, controllers, and...
This standard is applicable to ac contactors applied at voltages in the range of 1 501V to 15kV, and metal-enclosed contactor-based controllers, control centers, and other control assemblies and associated equipment applied...
Notice of Intent
Test methods for measuring power consumption ...
General The standard provides a unified best practice for measuring and reporting the power consumption of a range of three phase low voltage equipment where the equipment is not delivering an intended service to a user in...
Notice of Intent
Agricultural tractors and machinery -- Power ...
This part of ISO 500 specifies the dimensions of the master shield and clearance zones for rear-mounted power take-offs (PTO) of types 1 and 2 on narrow-track (track width 1 150 mm or less) agricultural tractors.