Standard for Manual Stations for Fire Alarm Systems...
1 SCOPE 1.1 This Standard covers manual stations and their accessories for installation in ordinary locations, indoor and outdoor, for use in fire alarm systems. 1.2 A manual station having a pre-wound signalling mechanism...
Notice of Intent
Instrument transformers - Part 3: Additional ...
This part of IEC 61869 applies to new inductive voltage transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. Note 301: Requirements specific to...
Notice of Intent
Instrument transformers — Part 5: Additional ...
This part of IEC 61869 applies to new single-phase capacitor voltage transformers connected between line and ground for system voltages Um ≥ 72,5 kV at power frequencies from 15 Hz to 100 Hz. They are intended to supply a low...
Notice of Intent
Preparation and quality management of fluids ...
This document is the base standard for a number of other standards dealing with water treatment equipment, water, dialysis water, concentrates, and dialysis fluid (ISO 23500 series) and provides dialysis practitioners with...
Notice of Intent
Preparation and quality management of fluids ...
This document is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies
Notice of Intent
Preparation and quality management of fluids ...
This document specifies minimum requirements for water to be used in haemodialysis and related therapies. This document includes water to be used in the preparation of concentrates, dialysis fluids for haemodialysis...
Notice of Intent
Preparation and quality management of fluids ...
This document specifies minimum requirements for concentrates used for haemodialysis and related therapies. This document is addressed to the manufacturer of such concentrates. In several instances in this document, the...
Notice of Intent
Preparation and quality management of fluids ...
This document specifies minimum quality requirements for dialysis fluids used in haemodialysis and related therapies. This document includes dialysis fluids used for haemodialysis and haemodiafiltration, including...
Notice of Intent
Standard for Intrusion Detection Units
1.1 These requirements cover intrusion detection units for burglary protection signalling systems to be employed in outdoor or ordinary indoor (non-hazardous) locations to automatically indicate the presence of an intruder by...
Notice of Intent
Belowground reinforced thermosetting resin conduit...
1.1 This Standard specifies the requirements for low-halogen belowground (Type BG) reinforced thermosetting resin conduit (RTRC) and fittings, for installation and use in accordance with CSA C22.1, Canadian Electrical Code...
Notice of Intent
Switches for appliances - Part 2-6: Particular...
Clause 1 of IEC 61058-1:2016 is applicable except as follows. Addition: This part of IEC 61058 is a subset based on IEC 61058-1. The clauses outlined below are intended to address the specific requirements for switches...
Notice of Intent
Cable Management Systems - Cable Ties for Electrical...
This document specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations. Cable ties and...