Notice of Intent
Standard for Integrated Systems Testing of Fire...
1.1 This Standard prescribes the methodology for verifying and documenting that all interconnections between systems provided for fire protection and life safety functions are installed and operating in conformance with their...
Notice of Intent
Standard for Sensor Operated Backwater Prevention...
1.1 This standard covers backwater prevention systems that use sensors, controls and mechanisms for the prevention of backflow for sanitary drainage and storm systems and specifies minimum requirements for materials...
Notice of Intent
Fire Tests- Full-Scale Room Test for Surface ...
Note: This notice of intent was withdrawn by the responsible SDO on June 20, 2023. This Standard specifies a test method that simulates a fire that under well ventilated conditions starts in a corner of a small room with a...
Notice of Intent
Standard for Manual Stations For Fire Alarm Systems...
This Standard covers manual station s and their accessories for installation in ordinary locations, indoor and outdoor, for use in fire alarm systems. A manual station having a pre-wound signalling mechanism and equipped with...
Notice of Intent
Live working - Methods for assessment of defects...
This document defines methods to assess defects and to verify that products after the manufacturer process meet the requirements of the corresponding product standard. The principles of assessment of defects for live working...
Notice of Intent
Standard Method Of Test For Fire Growth Of Mattresses...
1.1 The purpose of this test method is to investigate the ability of mattresses to resist rapid heat release by measuring specific fire test responses when the mattress or mattress set is subjected to a specified flaming...
Notice of Intent
Standard Method Of Test For Fire And Smoke Characteristics...
1.1 This test method is for use in determining values of flame propagation distance and smoke optical density for electrical and optical-fibre cables and non-metallic raceways that are to be installed in ducts, plenums, and...
Notice of Intent
Installation of Smoke Alarms
1.1 This Standard applies to the installation of smoke alarms within dwelling units as well as within sleeping rooms / areas that are not part of dwelling units. (Refer to Appendix A, Explanatory Material, Clause A1.1 and...
Notice of Intent
Press Connections
This Standard covers press connections made with: (a) copper or copper alloy fittings and Type K, L, and M copper tube; (b) carbon steel fittings and Schedule 10 and 40 carbon steel pipe; (c) stainless steel fittings and...
Notice of Intent
Chemical Dispensers with Integral Backflow Protection
Chemical dispensing systems (herein referred to as the “device”) provide a means of mixing potable water with chemicals to provide the user with a chemical solution which is ready for use. The amount of dilution shall be...
Notice of Intent
Performance Requirements for Dielectric Pipe ...
Note: The standard development activity of this Notice of Intent (originally published on June 14, 2022) was updated by the responsible SDO on March 21, 2023. This standard covers specifies requirements for materials...
Notice of Intent
Professional Qualifications Standard for Water...
This standard applies to an individual who is responsible for installation, of water treatment equipment. The purpose of this standard is to provide minimum performance criteria, identified by industry consensus, for Water...