Notice of Intent

Standard for Smoke Alarms

These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations and portable smoke alarms used as "travel" alarms in accordance with: In Canada: a)...
Notice of Intent

Standard for Fireplace Inserts

Note: The scope for this NOI (originally published on January 22, 2019) was updated by the responsible SDO on July 27, 2021. 1.1 These requirements cover prefabricated fireplace inserts and hearth-mounted stoves for masonry...
Notice of Intent

Standard for Carbon-Dioxide Fire Extinguishers

These requirements cover the construction and performance, exclusive of performance during fire tests, of portable carbon-dioxide fire extinguishers. Carbon-dioxide fire extinguishers are intended to be utilized in accordance...
Notice of Intent

Standard for Dry Chemical Fire Extinguishers

These requirements cover the construction and performance, exclusive of performance during fire tests, of portable dry chemical and dry powder (Class D) fire extinguishers. Dry chemical and dry powder fire extinguishers are...
Notice of Intent

Water Based Agent Fire Extinguishers

These requirements cover the construction and performance, exclusive of performance during fire tests, of portable water based agent fire extinguishers. These fire extinguishers are intended to be utilized in accordance with...
Notice of Intent

Standard for Verification of Fire Alarm Systems

1 Scope 1.1 This Standard prescribes inspection and test procedures for the purpose of verifying that the fire alarm system is installed in conformance with the design and CAN/ULC-S524, Standard for Installation of Fire Alarm...
Notice of Intent

Standard for Heat Detectors for Fire Alarm Systems

These requirements cover heat-actuated fire detectors intended for ordinary (nonhazardous) and outdoor locations, for use as components in automatic fire protective systems, to be installed in accordance installation in...
Notice of Intent

Test Method for Evaluating Roof Drain Performance

Note: This NOI was withdrawn by the responsible SDO on January 11, 2022. This Standard specifies a test method to determine roof drain systems performance by measuring flow rates based on the water head and the piping...