Refine Results
Displaying 9685 - 9696 of 11740
Notice of Intent
STANDARD FOR ABOVEGROUND STEEL TANKS FOR FUEL...
1 SCOPE 1.1 (REV1) This Standard covers the design and construction of aboveground steel non-pressure tanks intended for installation inside or outside buildings and for the storage of: A Combustible liquid intended to be...
Notice of Intent
Standard for Smoke Alarms
1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations and portable smoke alarms used as "travel" alarms in accordance with: a)...
Notice of Intent
Standard for Steel Underground Tanks for Flammable...
1.1 This Standard sets forth minimum design and construction requirements for non-pressure horizontal cylindrical steel tanks that are used for underground storage of flammable and combustible liquids. In addition to this...
Notice of Intent
Standard for Nonvolumetric Precision Leak Detection...
1.1 This Standard provides minimum requirements for primary containment leak detection that uses qualitative characteristics to detect leaks in the primary containment. NOTE: Depending on the design of the tank system, and...
Notice of Intent
Emergency Breakaway Fittings, Swivel Connectors...
1 Scope 1.1 This Standard sets forth minimum requirements for emergency breakaway fittings, swivel connectors and pipe-connecting fittings of the threadless compression type. Connectors and fittings covered by these...
Notice of Intent
Standard for Visible Signaling Devices for Fire...
Note: The project need for this NOI (originally published on July 5, 2023) was updated by the responsible SDO on July 11, 2023 . 1.1 This Standard applies to visual signaling devices intended for indoor and/or outdoor...
Notice of Intent
Standard for Meters for Flammable and Combustible...
1.1 These requirements cover: a) Meters for flammable and combustible liquids, of the type and size commonly used in the assembly of motor fuel dispensing devices; and b) Meters for liquefied petroleum gas (LP-Gas), of the...
Notice of Intent
Standard for Safety of Premises, Buildings and...
1.1 This Standard provides minimum requirements for the security of premises from intrusion and infiltration, as well as considerations for secure access and safe egress. 1.2 This Standard provides the criteria for the...
Notice of Intent
Standard for Organic Light Emitting Diode (OLED...
1.1 These requirements apply to organic lighting emitting diode (OLED) panels intended for task, ambient, or aesthetic illumination, and for portable or permanent installation in accordance with the following standards, and...
Notice of Intent
Standard Method of Test for the Evaluation of...
1.1 The purpose of this test method is to determine the contribution to fire growth of protective coverings over foamed plastic insulation when tested in a Full-Scale Room Test in accordance with CAN/ULC-9705, Fire Tests -...
Notice of Intent
Standard for Oil-Water Separators
1.1 (REV1) This Standard provides minimum requirements for shop fabricated single-wall or double-wall oil-water separators intended to collect and separate free oil from water by gravity separation at an inlet free oil...
Notice of Intent
Standard for Meters for Diesel Fuel, Biodiesel...
1.1 These requirements cover positive displacement liquid meters for use with motor fuels. Motor fuels, as defined by these requirements, include one or more of the fuels described in 1.2. 1.2 Meters for gasoline/ethanol...